BWQFH - KODAK CINEFLURE DEVELOPER AND REPLENISHER, PART B

  • MSDS: BWQFH
  • Manufacturer: EASTMAN KODAK COMPANY
  • Product Name: KODAK CINEFLURE DEVELOPER AND REPLENISHER, PART B
  • National Stock Number: 6750-01-377-3129
Product Identification

Product ID:KODAK CINEFLURE DEVELOPER AND REPLENISHER, PART B
MSDS Date:03/03/1993
FSC:6750
NIIN:01-377-3129
MSDS Number: BWQFH

Responsible Party
EASTMAN KODAK COMPANY
343 STATE STREET
ROCHESTER, NY 14650
US

Emergency Phone: 716-722-5151

Info Phone: 716-477-3194

Cage: 19139

Contractor
EASTMAN KODAK CO GOVERNMENT MARKETS CONTRACTS
ROCHESTER, NY 14650-1115 US

Telephone: 716-722-5151/(800) 242-2424

Cage: 19139

Ingredients

WATER

CAS: 7732-18-5

RTECS: ZC0110000

Fraction By Weight: 80-85%


ACETIC ACID (SARA III)

CAS: 64-19-7

RTECS: AF1225000

Fraction By Weight: 15-2040%

OSHA PEL 10 PPM

ACGIH TLV: 10 PPM/15 STEL; 9394

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS

Hazards

Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHALATION-VAPOR IRRITATING. MAY CAUSE
IRRITATION TO THE MUCOUS MEMBRANES & UPPER RESPIRATORY TRACT.
SKIN-CAUSES IRRITATION. INGESTION-HARMFUL IF SWALLOWED.
Explanation of Carcinogenicity:THIS COMPOUND CONTAINS NO KNOWN
CARCINOGENS OR SUSPECT CARCINOGEN.
Effects of Overexposure:EYES-CAUSES BURNS. VAPOR CAUSES EYE IRRITATION
AND TEARING. INGESTION-MAY CAUSE BURNS OF THE GASTROINTESTINAL
TRACT IF SWALLOWED.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INHALE-MOVE TO FRESH AIR. TREAT SYMPTOMATICALLY. GET MEDICAL
ATTENTION IF SYMPTOMS OCCUR. EYE-IMMEDIATELY FLUSH WITH WATER FOR
15 MIN. GET MEDICAL ATTENTION. SKIN-IMMEDIATELY FLUSH WITH WATER
WHILE RE MOVING CONTAMINATED CLOTHING/SHOES. GETMEDICAL ATTENTION
FOR SKIN REACTIONS. INGESTION-DO NOT INDUCE VOMITING. GIVE VICTIM A
GLASS OF WATER. CALL A PHYSICIAN OR POISON CONTROL CENTER
IMMEDIATELY.

Fire Fighting

Flash Point:NONE
Extinguishing Media:USE APPROPIATE AGENT FOR ADJACENT FIRE.
Fire Fighting Procedures:WEAR SELF-CONTAINED BREATHING APPARATUS AND
PROTECTIVE CLOTHING.
Unusual Fire/Explosion Hazard:NONE.

Accidental Release

Spill Release Procedures:NEUTRALIZE WITH SODIUM BICARBONATE. FLUSH TO
SEWER WITH LARGE AMOUNTS OF WATER.

Handling

Handling and Storage Precautions:KEEP CONTAINER CLOSED. KEEP AWAY FROM
INCOMPATIBLE SUBSTANCES.
Other Precautions:DO NOT GET IN EYES AND AVOID CONTACT WITH SKIN AND
CLOTHING. AVOID BREATHING VAPORS. USE WITH ADEQUATE VENTILATION.
WASH THOROUGHLY AFTER HANDLING.

Exposure Controls

Respiratory Protection:IF ENGINEERING CONTROLS DO NOT MAINTAIN AIRBORNE
CONCENTRATIONS BELOW RECOMMENDED EXPOSURE LIMITS, AN APPROVED
RESPIRATOR MUST BE WORN. RESPIRATOR TYPE: ORGANIC VAPOR.
Ventilation:GOOD GENERAL VENTILATION (TYPICALLY 10 AIR CHANGES PER
HOUR) SHOULD BE USED.
Protective Gloves:WEAR IMPERVIOUS GLOVES
Eye Protection:WEAR SAFETY GLASSES WITH SIDE SHIELD
Other Protective Equipment:EYE BATH, SAFETY SHOWER, WASHING FACILITIES.
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING AND BEFORE
EATING, DRINKING OR SMOKING. LAUNDER CONTAMINATED CLOTHING BEFORE
REUSE.
Supplemental Safety and Health
NONE

Chemical Properties

HCC:C2
Boiling Pt:B.P. Text:>212F,>100C
Vapor Pres:24 MBAR
Vapor Density:0.6
Spec Gravity:1.02
pH:<2
Solubility in Water:COMPLETE
Appearance and Odor:LIQUID. COLORLESS. VINEGAR.
Percent Volatiles by Volume:100

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS, BASES.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:NONE

Disposal

Waste Disposal Methods:DISCHARGE, TREATMENT OR DISPOSAL MAY BE SUBJECT
TO NATIONAL, STATE OR LOCAL LAWS. NEUTRALIZE WITH SODIUM
BICARBONATE. FLUSH TO SEWER WITH LARGE AMOUNTS OF WATER.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.